Spec 70168 bus drop cable industrial grade construction.
Bus drop cable nec.
Bus drop cable and tray cable are service cords that connect a power supply to a machine or device.
The 1996 nec allowed one building surface attachment.
The 1999 nec now refers only to sec.
Bus drop cable and tray cable are service cords that connect a power supply to a machine or device.
Bus drop cable is made for use in indoor or outdoor applications for connection of stationary or portable equipment to facilitate relocation of equipment.
Stranded bare copper per astm b 8 2.
60 c 140 f 75 c 167 f 90 c 194 f 60 c 140 f.
They have two or more insulated conductors and a protective jacket that resists abrasion water sunlight and lubricants.
Bus drop cable pvc insulation pvc jacket applications.
Bus drop cable is typically used as a branch connection from a ceiling cable while tray cable is primarily used for wiring.
Acic pcs duo power control signal cable csa view pdf.
For use as drop cable from overhead bus duct to floor machines.
Aluminum conductors copper clad conductors.
It is constructed using sizes 14 awg through 2 awg annealed stranded bare copper.
This cable is rated for indoor and outdoor use in wet or dry locations.
Bus drop cable is typically used as a branch connection from a ceiling cable while tray cable is primarily used for wiring.
Bus drop cable 60 c 600 volt ul.
Nec 364 8 as branch wiring from busways.
The cable is covered with a gray pvc jacket.
Royal bus drop view pdf.
Easily disconnected and connected when machines are moved.
Resistant to oil grease acids cutting fluids and mechanical abuse.
They have two or more insulated conductors and a protective jacket that resists abrasion water sunlight and lubricants.
Ampacities are from table 310.
Bare stranded copper.
Installed quickly without use of conduit for fixed or temporary power.
At least one leading national authority says you re only allowed to make such extensions from busways.
364 8 in the busway article.
Allied wire and cable s bus drop cable is designed for both indoor and outdoor use in wet or dry locations for the connection of portable or stationary equipment to facilitate their interchange our particular bus drop cable is constructed with a polyvinylchloride jacket and depending on the awg has a temperature rating of either 60 ºc or 75ºc and a voltage rating of 600 volts.
Pvc colors black white red 3.
Construction applications standards q a.
This comes up in locations where you d like to attach the drop to the wall from a wireway run overhead at a central point.